Daily from 9 a.m. to 6 p.m.
Moscow time
Kinesis biofeedback complex has proven itself over many years to be a very convenient, reliable and accurate tool designed for conducting BFB trainings via EEG (electroencephalogram), EMG (electromyogram), and ECG (electrocardiogram – heart rate and stress index parameters) channels.
MD type code: 358220 (system of psychophysiological training using the Kinesis biofeedback method).
Kinesis biofeedback system is a modern wired system of psychophysiological training and correction of various psycho-emotional and functional disorders in a wide range of diseases of the nervous, musculoskeletal and autonomic (cardiovascular) systems of the body.
The BFB method develops the skill of control and regulation of the patient’s target parameters. The system can be used with equal high efficiency for both adult and child patients.
The system allows to conduct:
Any combination of EEG, EMG and ECG signals recorded from one subject is possible for the purpose of conducting multimodal training. Such trainings can be used to develop complex reflex reactions and skills, fine motor coordination, or other specific psychophysiological tasks.
The choice of training is made from a pre-installed library of courses developed by specialists and easily selected by name (depending on the rehabilitation purposes). Pre-created training templates allow to conduct training sessions taking into account the gradual complication of tasks. The presence of pre-installed courses makes it possible to conduct BFB training with a large number of patients, which is an indispensable aid for a physician assistant (nurse, exercise therapy instructor). Additionally, it is possible to create original courses for different rehabilitation tasks.
The advantage of this system is an intelligent mathematical model that describes real parameters of the muscle, brain biopotentials or ECG before the start of the BFB training session. This model, being a basic reference signal system, allows for adaptation to the individual characteristics of a patient, which increases the accuracy of physiological perception and helps develop the correct training pattern.
BFB training via the EMG channel is used to restore various types of motor functions, correct damaged muscle fibers and nerve trunks:
BFB training via the EEG channel allows for the correction of dynamic indicators (neurodynamic parameters) of the cortical bioelectrical activity of the brain areas involved in the pathological process.
Psycho-emotional correction using the BFB system is necessary for children, healthy adults and people with any psycho-emotional illnesses.
1. For children, courses are necessary for:
2. For people with psycho-emotional disorders, the courses are developed for:
3. For healthy people, the courses help to:
BFB training via the ECG channel is used to correct psychovegetative indicators obtained on the basis of statistical calculation of the parameters of the RR interval series:
Primary indications:
Multimodal training sessions combining EEG and EMG can be used:
Key software functions:
Database functionality:
| Number of universal channels | 4 pcs |
| Operating frequency band of the amplifier (at -3 dB level) | 0 – 10 kHz |
| Sampling rate for each channel | 40 kHz |
| Range of amplitudes of measured signals | 0,1 µV – 200 mV |
| ADC dynamic range | 100 dB |
| ADC bit capacity | 24 |
| Lower bandwidth limit | 0 Hz – 1000 Hz |
| Upper bandwidth limit | 1 Hz – 10000 Hz |
| Frequency band of displayed EMG signals (software-controlled) | 10 – 400 Hz |
| Frequency band of displayed EЕG signals (software-controlled) | 1 – 30 Hz |
| Frequency band of displayed CIG signals (software-controlled) | 5 – 40 Hz |
| Kinesis hardware unit | 1 pc. |
| PC connection cable (USB A-B) | 1 pc. |
| Lead wire for EMG electrodes | 3 pcs. |
| Adapters for disposable EMG electrodes | 8 pcs. |
| Combined wire for EEG electrodes | 2 pcs. |
| EEG electrodes | 5 pcs. |
| Ear adapters with electrodes | 2 pcs. |
| Tape fixing EEG electrodes | 3 pcs. |
| Wire for general EEG or EMG electrode | 2 pcs. |
| Common electrode with a fixation tape | 2 pcs. |
| Lead wire for ECG electrodes | 2 pcs. |
| Cardiointervalographic electrodes for limbs (clamps) | 4 pcs. |
| Set of disposable electrodes (50 pcs.) | 1 pack |
| Electrode gel | 1 pc. |
| Syringe with needle for gel injection | 1 pc. |
| Specialized stand for the device | 1 pc. |
| Flash memory stick with software | 1 pc. |
| Operational documentation | 1 set |
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply
During system development, a number of unique technical solutions were used, enabling to record the highest quality signal with an extremely low level of noise and interference
These solutions have proven their effectiveness over many years of operation
The software contains a pre-installed library of courses, specifically aimed at a specific range of rehabilitation tasks
The convenient, flexible and intuitive interface of the program allows you to quickly start a rehabilitation session using the BFB method
At the end of each training session, the system automatically generates an extended report that objectively and clearly presents the effectiveness of the work done, which increases the patient’s motivation and involvement in the rehabilitation process
Введите номер телефона и мы Вам перезвоним в ближайшее время!
Ваш запрос принят!
С вами свяжутся в ближайшее время.
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply