Biofeedback system Kinesis for psycho emotional correction

Download booklet, 1,6 General Biofeedback theory (study guide), 232 Registration certificate, 136 Declaration of compliance, 684

Biofeedback system Kinesis for psycho emotional correction is a modern psychophysiologic training system for treatment of different functional derangement which can be observed during patient suffers from different kinds of the nervous system disorders, and psycho emotional disorders as well.

Operating with our biofeedback system a doctor can perform psycho emotional correction on the basis of EEG registration and interpretation. During training process a patient is able to change parameters of brain functional activity consciously. Doing it he is changing the level of activity of relaxing non specific brain systems.

This method of correction, treatment and training is the most effective and is recommended when a patient suffers from different types of neurosis, neurasthenic conditions, psycho vegetative disorderes, sleep disturbance, distress syndrome, and misadaptation after intensive physical exercises.

The method has the great significance in complex correction of psycho emotional disorders evoked by neurosis and consequences of stressful affective conditions.

The biofeedback system is characterized by high precision of physiological parameters registration in real time without modulating fouling of signal during signal processing. Operating with our biofeedback system a doctor can perform the high quality precise registration of individual brain and muscles electrical signal parameters because our system is designed on the basis of modern digital components.During a biofeedback training process the system for intellectual analysis of brain electrical activity is being adopted to patient individual parameters which are being calculated in real time. Because of high precision of signal registration it is possible to form the adaptive response of a functional system which is being trained and a new determinant program of patient higher nervous activity.

So patients can analyze peculiarities of own physiological processes in real time and influence on them in an interactive mode.

Application spheres

  • Pediatric and general neurology;
  • Neurosurgery;
  • Traumotology and orthopaedics;
  • Sports medicine;
  • Rehabilitation medicine;
  • Pediatrics;
  • Therapy treatment;
  • Applied medical psychology;
  • Cabinets for psychological relax.

Functions and capabilities

The system enables biofeedback training on the basis of electroencephalography signals. The analyzer Kinesis is used for biopotentials registration and allows carrying out correction on the basis of two EMG channels. The analyzer is connected with a personal computer through the USB data interface unit.

 The
The "Run"game

Software for biofeedback system is presented as a collection of computer acoustic and visual acts which were designed in a game form. A patient can influence on these acts by changing of physiological parameters of his functional condition (level of brain activity, muscle tension, pulse parameters etc.). During controlling process a patient should find normal positive result which will be displayed on a computer screen in an understandable and comfortable form and inform a patient about changing of functional parameters of investigated organ (muscle, brain, heart).

A games situation increases the level of receptivity to represented information and patient motivation to training especially for children.

The Flight game
The Flight game

It is possible to institute one time therapy or a course of treatment. An in-built expert system allows a doctor to study patient possibilities and to perform training according to this information.

EEG biofeedback system allows correcting neurodynamic parameters of cerebral cortex bioelectric activity within brain zones, involved in pathologic process. Learning procedure is based on EEG spectral estimation. There is also an expert system that estimates bioelectrical activity of a person undergoing a medical treatment.

 The Swab game
The Swab game
It is the main different between our biofeedback system and systems produced by other firms that Kinesis has in-built technical biofeedback system which produces light cycling impulses in dominant frequency spectrum of patient brain EEG rhythms which is adopted by brain within relaxing. It increases the quality of psycho relaxation achievement, its degree and intensity.

Software

Software the biofeedback system is controlled under is full-function in no low than the Windows 7 environment. Biofeedback system program is user-friendly that is the main unique feature of the software. There are no other requirements for operating with software for a doctor except to being computer literate. The program is operated by a doctor and a patient as well in special modes. There is an option of using of two computers with one device. In this case a doctor operates one of these two computers and with own modes, also a patient operates another computer. The main window of the biofeedback system program is similar to Windows desktop environment. It is possible to do the following acts in the main window:

  • To open the patient database;
  • To perform the biofeedback training;
  • To read the software description;
  • To watch the contact data.

The database is used for patient data input, for patient data and investigation results storage as well. There are no requirements to use the database because the system is referred to training equipment. But in case of need there is function of report card forming containing dynamics of changing of training results.

In training mode a doctor is able to analyze a signal, to get a model of trained organism systems condition (it is EEG activity index for brain), to control activity level of patient and to start a game. Then a patient begins playing the game.

Delivery set
Complex biofeedback system Kinesis consists of the following parts:
hardware module, able to registrate 4 (four) EEG channels, 1 (one) Cardiointerval recording;
electroencephalographic set of electrodes (cup electrodes) with sling for fixing;
EEG electrode set (button configuration) with slam for fixing;
ECG electrodes set for human limbs (pins);
special device holder;
software, visualizing, recording and charging at database, maths analysis and creation of report form, developed to WINDOWS software (not less than Windows 7);

For the system functioning you need a personal computer or a notebook with the following configuration:

  • Processor with bit-timing frequency not less than 2 GHz and not less than 2 core processor.
  • RW memory not less 2 Gb.
  • 2 monitors or notebook monitor and standard apart monitor, with screen saver 1024 pixels in horizontal and not less 768 pixels in vertical direction both.
  • Quantified (external/out) video card with memory minimum 512 Mb.
  • hard disk drive minimum 320 Gb
  • Speakers.
  • Printer for reports (optional)
  • Operation system Windows 7
  • Work program for all devices is delivered on DVD-ROM disk, that is why you need DVD.
  • Free usb port for a computer to hook into BOS system.

BOS complex can be provided to clients computer, but system delivery with computer and printer is recommended:

  • RAM (random access memory) not less than 2 GB and more;
  • Video card Gforce 6600 or ATI Radeon 9600;
  • Hard drive memory not less than 80 GB;
  • A computer display monitor with addressability no low as 1280 1024 32 bit.
  • The system is installed on a clients computer but delivery of the system with a computer and a printer is recommended.

    HARDWARE BLOCK
    Number of channels4
    Working bank of reinforce (on level 3 dB) 0-10 khz
    Sampling rate for each channel 40 kHz
    Input noise mean square value Not more than 6 uV;
    Range of signal amplitudes 0,1 uV 200 mV;
    ADC dynamic range 100 dB;
    ADC number of bits 24
    Upper bound of bandwidth 0 1 kHz
    Low bound of bandwidth 1 Hz 10 kHz
    Additional rejector filters for frequencies 50Hz, 100 Hz, 150 Hz, 200 Hz, 250 Hz.
    Electrostastic discharge tolerance 15 kV
    Supply voltage +5 V (from USB of PC)
    Dimension 225 x 220 x 72 mm
    EEG channels
    Number of channels 4
    Frequency band (by a program control) 1 - 30 Hz
    Amplitude range (by a program control) +/- 10 uV +/- 500 uV
    KIG channels
    Number of channels 1
    Frequency band (by a program control) 5 - 40 Hz
    Amplitude range (by a program control) +/- 100 uV +/- 5 mV

    Delivery conditions

    Guarantee period 3 years.

    If you need, our specialists can visit you and set or study system skills at clients workplace.

    In this case you should pay travel expenses and specialists work.

    If necessary you can take part in organized group studies by "Neirotech"specialists in Taganrog, in Pyatigorsk or in St. Petersburg.

    Delay in paying till the fact of delivery is possible.

    Delivery period for client 10 days from the day of payment or signing contract.

    Distributors have discount 15% and higher.