Biofeedback Rehabilitation Psychophysiological Training Complex (Recommended for recessionary childbearing Centers)

Creation of Medico-social Centers helping pregnant women who are in a pressing situation is one of the most popular concepts in modern maternity obstetric service in todays Russia. Such Centers are aimed at helping hard-pressed pregnant women in medical, social, psychotherapeutic (psychological), legal respects. The target audience for such Centers are women, who have decided to terminate pregnancy.

In accordance with the law of medical help in Obstetrics and Gynecology (apart from using the assisted reproductive treatment) , approved by Ministry of Health of the Russian Federation dated November 01, 2012 572n, that is a part of standard, the Centers of Medical and Social support for hard pressed pregnant women, have to be equipped with psychophysiological rehabilitation Complex for training with biofeedback.

The complex core capabilities are:

Download booklet, 1,2
  • to organize psychological rehabilitation for hard pressed pregnant women;
  • to carry out relaxation;
  • to build up stress resistance;
  • to reduce anxiety;
  • to fulfill supplement function for realizing supplement therapy of long-lasting Rest Deficit Disorder and common psychosomatic activity.

All above mentioned functions provide for Recovery psychophysiological complex for training with biofeedback system realizing Kinezis.

General information

Relaxation is a tension-relieving effect, resting condition, enervation that becomes owing to relaxation after stresses and physical activities. A relaxation can be reflexive enervation before going to sleep, and non-reflexive caused by striking calm pose, visualization, relaxation of the most active muscles.

One of the most effective method of relaxation is biofeedback initiation with help of devices, that fix biological activity level and make it perceivable for a trainee.

Rehabilitation psychophysiological complex for training with biofeedback system Kinezis is a modern system of psychophysiological training and functional illness treatment for wide range of neuropathy, also used to correct psycho-emotional disorders.

BOS capabilities:

  • Psychoemotional correction based on registration and encephalon biopotential analyses;
  • Psychovegetative correction based on cardiac rhythm measure.

Psychoemotional correction, based on registration and encephalon biopotential analyses takes the most important place in neurosis therapy and in psycho-emotional disorders as devices psychotechnical procedure of relaxation and/or in raising your attention on senses and it develops skills of self-realization and stress-resistance.

Psychovegetative correction, based on cardiac variability rhythm measure, indicates the way heart compensates for emotional changes. It also illustrates heart mental and physical stress and trains to return into a more relaxed and efficient condition.

Such procedure helps to gain full relaxation and save cardiovascular system.A training, based on signal parameters, shows reaction approximation of a body and its adaptation possibilities. For the first time such analysis was used in astromedicine while training of readiness rating of astronauts for a flight. Also astronauts availability trained for stresses. The method was particular for registry easiness, information fastness and restudy opportunity.

Significantly, there are no special claims for the placement location of the Rehabilitation psychophysiological complex for training with biofeedback system. The system needs neither an isolated room nor any additional electric installation; it requires no special computer skills. The system has been simplified for exploitation and is easy to learn

Prescriptions and opportunities

Rehabilitation psychophysiological complex for training with biofeedback system Kinezis allows for training with biofeedback, based on electroencephalographic and ardiointervalographic (RR-interval set) signals.To register biopotential a hardware unit which allows correction based on four universal channels is used.Hardware module connects to a PC with USB.

The Flight game
The Flight game

The system software is a set of special developed computer visual and acoustic effects in the form of a game. A patient is able to influence it by his mind activation.

 The Swab game
The Swab game

While processing for the project a patient finds usable positive result, that is reflected on the computer screen and the results of functional parameters of brain are shown in practical and understandable form.

Game situations can raise sensitization of represented information and training motivation, especially with children. It can be a one-time prescription as well as protracted treatment. Expert engineered allowes to determine a patient's ability and to conduct training accordingly.

Software

The software the biofeedback system is controlled under is full-function in no low than the Windows 7 environment. The biofeedback system program is user-friendly that is the main unique feature of the software. There are no other requirements for operating with the software for a doctor except to being computer literate. The program is operated by a doctor and a patient as well in special modes. There is an option of using of two computers with one device. In this case a doctor operates one of these two computers and with own modes, also a patient operates another computer. The main window of the biofeedback system program is similar to the Windows desktop environment.It is possible to do the following acts in the main window:

  • To open the patient database.
  • To perform the biofeedback training.
  • To read the software description.
  • To watch the contact data.

The database is used for patient data input, for patient data and investigation results storage as well. There are no requirements to use data base because the system is referred to training equipment. But in case of need there is a function of report card forming containing dynamics of changing of training results.

Delivery set
Complex biofeedback system Kinesis consists of the following parts:
hardware module, able to registrate 4 (four) EEG channels, 1 (one) Cardiointerval recording;
electroencephalographic set of electrodes (cup electrodes) with sling for fixing;
EEG electrode set (button configuration) with slam for fixing;
ECG electrodes set for human limbs (pins);
special device holder;
software, visualizing, recording and charging at database, maths analysis and creation of report form, developed to WINDOWS software (not less than Windows 7);

For the system functioning you need a personal computer or a notebook with the following configuration:

  • Processor with bit-timing frequency not less than 2 GHz and not less than 2 core processor.
  • RW memory not less 2 Gb.
  • 2 monitors or notebook monitor and standard apart monitor, with screen saver 1024 pixels in horizontal and not less 768 pixels in vertical direction both.
  • Quantified (external/out) video card with memory minimum 512 Mb.
  • hard disk drive minimum 320 Gb
  • Speakers.
  • Printer for reports (optional)
  • Operation system Windows 7
  • Work program for all devices is delivered on DVD-ROM disk, that is why you need DVD.
  • Free usb port for a computer to hook into BOS system.

BOS complex can be provided to clients computer, but system delivery with computer and printer is recommended:

  • RAM (random access memory) not less than 2 GB and more;
  • Video card Gforce 6600 or ATI Radeon 9600;
  • Hard drive memory not less than 80 GB;
  • A computer display monitor with addressability no low as 1280 1024 32 bit.
  • The system is installed on a clients computer but delivery of the system with a computer and a printer is recommended.

    HARDWARE BLOCK
    Number of channels4
    Working bank of reinforce (on level 3 dB) 0-10 khz
    Sampling rate for each channel 40 kHz
    Input noise mean square value Not more than 6 uV;
    Range of signal amplitudes 0,1 uV 200 mV;
    ADC dynamic range 100 dB;
    ADC number of bits 24
    Upper bound of bandwidth 0 1 kHz
    Low bound of bandwidth 1 Hz 10 kHz
    Additional rejector filters for frequencies 50Hz, 100 Hz, 150 Hz, 200 Hz, 250 Hz.
    Electrostastic discharge tolerance 15 kV
    Supply voltage +5 V (from USB of PC)
    Dimension 225 x 220 x 72 mm
    EEG channels
    Number of channels 4
    Frequency band (by a program control) 1 - 30 Hz
    Amplitude range (by a program control) +/- 10 uV +/- 500 uV
    KIG channels
    Number of channels 1
    Frequency band (by a program control) 5 - 40 Hz
    Amplitude range (by a program control) +/- 100 uV +/- 5 mV

    Delivery conditions

    Guarantee period 3 years.

    If you need, our specialists can visit you and set or study system skills at clients workplace.

    In this case you should pay travel expenses and specialists work.

    If necessary you can take part in organized group studies by "Neirotech"specialists in Taganrog, in Pyatigorsk or in St. Petersburg.

    Delay in paying till the fact of delivery is possible.

    Delivery period for client 10 days from the day of payment or signing contract.

    Distributors have discount 15% and higher.